    Care and Repair

    A few habits keep your PORTALO working for years. If something goes wrong, most issues take a few minutes to fix at home.

    Care

    After the beach or a river

    Sand, mud and salt water are the main enemies of the valve. Sand can stop it from closing, and debris in the nozzle can block the mist mode.

    • Rinse the reservoir, the hose and the nozzle with fresh water.
    • Shake out any sand and let it dry open.

    To protect the system, use the Sand Filter, especially when you fill it from a river or a lake. It stops sand and large particles before they reach the nozzle.

    placeholder image

    After use in the toilet

    • Rinse the nozzle and the hose with clean water.
    • Clean them with water, mild soap and a soft cloth. No chemicals, abrasives or solvents.
    • Wipe them dry before putting the hose back inside.
    placeholder image

    After everyday use

    • Do not leave it pressurized: unscrew the bottle slightly until you hear a hiss.
    • If you will not use it again soon, empty the remaining water.
    • Let it dry open, away from heat and direct sun.
    • Carry it upright.
    placeholder image

    Storing it for a long time

    • Empty it, release the pressure and let it dry completely.
    • Keep it away from heat and sunlight.
    • Rinse it with clean water before using it again.

    Troubleshooting common issues

    The pump no longer pushes air

    The pump seal may be too dry and dislodged after frictioning inside the tube.

    1. Unscrew the bottle.
    2. Unscrew the pump tube.
    3. Check the pump seal and remove any debris.
    4. If it looks dry, add food-grade grease at the base of the cylinder: 1 to 2 drops, or a pea-sized amount at most.
    5. Move the pump up and down a few times. The seal spreads the grease along the tube.
    6. Screw everything back on.

    With too much grease, the pump bounces back a little because there is less friction. It is not a real problem, but a small amount works best.

    Grease: use a food-grade silicone grease. We will add soon a maintenance kit in the shop. Until then, some classic greases can be found in grocery or drugstores. Make sure to not drink from the water if the grease is not food-safe.

    placeholder image

    You pump but it does not build pressure

    If you hear air escaping (pssht), pump pushes air but a seal is not sealing properly. Check these 3 seals, in this order.

    1. The bottle seal. The large ring inside the top that the lip of the bottle presses against, like on any water bottle. Make sure it is in place, clean and flat.
    2. The hose seal. Check the seal and the opening the hose slides through: there must be no sand, hair or debris on either. Wet it with a little water to help it seal.
    3. The pump tube seal. Rarely the cause, but check that it is in place and not dry.

    Then screw the bottle back on firmly and pump again.

    placeholder image

    The mist mode no longer works

    If you only get a direct jet, sometimes leaning to one side, debris is stuck in the nozzle head.

    Unscrew the nozzle head by one full turn, rinse it under a tap and remove any debris you can see inside.

    placeholder image

    The nozzle will not stop spraying

    Sand or debris is probably stuck in the valve, so it cannot close and PORTALO sprays until the bottle is empty. Try these steps in order, and stop as soon as it works.

    1. Rinse the nozzle head. Unscrew the nozzle head by one full turn and rinse it under a tap. Look inside and remove any visible debris.

    2. Rinse the whole showerhead. If it is sand, unscrew the complete showerhead and rinse it generously under a tap.

    3. Clean the valve. Unscrew the magnetic cap with a firm twist: there is a dot of glue on its thread from the factory, so it does not come loose by accident. Pull on the spring and the brass rod comes out. It has 3 seals.

    • Remove any debris from the rod, the seals and inside the circuit.
    • Rinse everything generously.
    • If the seals look dry, spread a little food-grade grease on them with your finger. It helps them last.
    • Put everything back in place.
    • Add a small dot of glue on the thread of the cap. Avoid superglue: it seals the cap for good.
    • Screw the cap back on firmly, without forcing.
    placeholder image

    The hose came off the showerhead

    This is a safety feature: if the showerhead is pulled very hard, the hose comes off instead of breaking. It takes a lot of force.

    1. Unscrew the base of the showerhead.
    2. Insert the hose inside. It must not stick out past the inner surface.
    3. Screw the base back on. It should not resist too much. If it does, pull the hose back slightly.
    4. Screwing the base back on creates the seal. Check that the hose comes out straight.
    placeholder image

    It leaks when the hose is pushed back inside

    Check the seal at the base of the showerhead. It seals the bottle when the hose is pushed back inside.

    • Make sure it is there and not too dry.
    • Remove any debris.

    Ideally, push the hose back inside once the bottle is empty. You can also do it with water still inside, as long as this seal is in good shape.

    placeholder image

    Still not working?

    Write to us at hello@getportalo.com with a photo or a short video. We will help you fix it.

    Spare parts (bottle, pump piston, pump housing, showerhead) will be available in our replacement parts.

    Your PORTALO has a 24-month warranty against manufacturing defects, in addition to legal guarantees. Keep your proof of purchase.

    Safety and hygiene

    Safety

    • Never point at the eyes or face.
    • Stop pumping at strong resistance.
    • Release the pressure before opening, away from your face.
    • Keep the magnets away from pacemakers.
    • Keep out of reach of young children.
    • Clean water recommended, 55 °C / 130 °F max.
    • No chemicals, carbonated drinks or dry ice.
    • No hot car, direct sun, microwave, freezer or dishwasher.
    • Do not use if cracked or damaged.
    • Do not leave pressurized after use. Carry upright.

    Hygiene use only

    PORTALO is designed for hygiene and cleaning, not drinking. It does not purify or disinfect water.

    • Do not drink water from the reservoir, even if it was drinkable at first. The hose may bring in contaminants from outside.
    • Never drink water from uncertain sources: rivers, lakes, snow, ice or unsafe tap water.